Duct Leakage Testing in Sandwich, MA — Stretch Code HERS 42/45

RESNET-certified duct leakage (duct blaster) testing for new construction, HERS Ratings, Mass Save programs, and MA Stretch Code compliance in Sandwich, MA.

RESNET Certified
Mass Save Qualified
24-Hour Reports
Duct Blaster Certified
Serving Sandwich, MA

2026 Massachusetts Energy Code Facts — Sandwich

Sandwich enforces the Massachusetts Stretch Energy Code (225 CMR 22), adopted effective 1/1/2023. Under the 2025 code update (current for 2026 permits), new homes in Sandwich must reach a maximum HERS Index of 42 (mixed-fuel) or 45 (all-electric) — up to 48 with qualifying credits — verified by a RESNET-certified HERS rater. ADUs must meet HERS 52–58, and major alterations, additions or change-of-use projects HERS 65–75, depending on fuel type and on-site solar.

  • Energy code status: Stretch Code (effective 1/1/2023) — 1 of 242 MA municipalities (as of the June 2026 Mass.gov adoption list).
  • Required testing & verification: blower door (air infiltration) testing, duct leakage testing, balanced mechanical ventilation (ERV/HRV), plus EV-ready and solar-ready provisions on the HERS compliance path. Under IECC 2021, total duct leakage may not exceed 4 CFM25 per 100 sq ft of conditioned floor area.
  • Mass Save® 2026 new-construction incentives: up to $25,000 per all-electric single-family home (Passive House tier; $7,500 base tier, $15,000 ENERGY STAR® NextGen tier — HERS ≤45), up to $40,000 for a 4-unit building, up to $3,750/unit for 5+ unit multifamily, and up to $30,000 for major all-electric renovations. Every tier requires enrollment and verification by an approved HERS rating company.

Related Sandwich services: HERS Rating Sandwich · Blower Door Testing Sandwich · Stretch Code Compliance Sandwich · MA Energy Codes Guide — or get a free quote from our RESNET-certified team (617-584-1809).

Sources: 2025 DOER Massachusetts Stretch & Specialized Codes Technical Guidance (Sept 2025); Mass.gov Building Energy Code Adoption by Municipality (June 2026); Mass Save 2026 Residential New Construction program.

HERS Rating Sandwich MA — duct leakage testing for an energy efficient home in Sandwich, Massachusetts
On-site duct leakage testing by our RESNET-certified team serving Sandwich, Massachusetts.

Common Questions About the Sandwich Energy Code

Is a HERS rating required in Sandwich, MA?

Yes. Sandwich has enforced the Massachusetts Stretch Energy Code since 1/1/2023, so new dwellings need a certified HERS rating from a RESNET-accredited rater — with blower door and duct leakage testing — before the certificate of occupancy.

What HERS index do new homes in Sandwich need to hit?

Homes permitted in Sandwich today must score HERS 42 or lower (mixed-fuel) or HERS 45 or lower (all-electric), up to 48 with qualifying credits. ADUs fall in the HERS 52–58 range and major alterations/additions in the 65–75 range, depending on fuel type and on-site solar.

What building energy code is Sandwich on right now?

Sandwich is one of 242 of Massachusetts’ 351 municipalities enforcing the Stretch Energy Code (225 CMR 22) per the June 2026 Mass.gov adoption list; 60 towns have gone further to the Specialized Code and 49 remain on the Base Code.

Official Maximum HERS Index Scores (Table R406.5)

These are the official maximum HERS Index scores that apply to projects in Sandwich under Table R406.5 of the current code (2025 DOER Technical Guidance):

Building typeNew construction (permits after 7/1/2024)New construction w/ embodied-carbon credit (R406.5.2)Accessory Dwelling UnitsMajor alterations, additions, change of use
Mixed-fuel building42455265
Mixed-fuel + solar electric42455570
All-electric building45485570
All-electric + solar electric45485875

Scores are measured before counting on-site renewable generation (per R406.5). Historic buildings may opt out for alterations under R503.1.1. Embodied-carbon credits (+3 points) come from low-GWP concrete and insulation EPDs per Table R406.5.3/R406.5.4.

Complete Stretch Code Compliance Requirements in Sandwich

Beyond the HERS maximums above, every new dwelling in Sandwich on the HERS pathway must satisfy four code sections — R403.6 (Ventilation), R404.4 (EV Ready), R406 (HERS) and Appendix RB (Solar Ready) — per the 2025 DOER Technical Guidance:

  • Balanced mechanical ventilation (R403.6): an ERV or HRV system meeting minimum system airflow, heat/energy-recovery efficiency, fan sound ratings and regulated air-inlet and exhaust locations — verified by field testing.
  • EV-Ready parking (R404.4): pre-wiring with a connection point and dedicated electrical panel capacity for future vehicle charging.
  • Solar-Ready roof (Appendix RB): a dedicated solar zone with structural-load verification, an electrical interconnection pathway and reserved panel space — unless the project installs solar directly.
  • Air-tightness & duct sealing: blower door result of 3.0 ACH50 or lower (Climate Zone 5) and duct leakage within 4 CFM25 per 100 sq ft.

Passive House alternative (R405): Phius or PHI certification satisfies the code in Sandwich in place of a HERS score — with a Certified Passive House Consultant for design and a Phius Certified Verifier/Rater during construction — and still requires EV-Ready and Solar-Ready compliance. Prescriptive path: allowed only for buildings without individually separate dwelling units, additions, and alterations — and a whole-building prescriptive project must implement 2 of the 3 additional-efficiency packages in R408 (enhanced envelope, higher-efficiency HVAC, or reduced water-heating energy). Additions of 1,000 sq ft or more (or exceeding 100% of the existing floor area) must meet both R502.3 prescriptive and the R406.5 HERS limits. Level III alterations (work area over 50% of the home and over 1,000 sq ft) also trigger HERS compliance; historic buildings are exempt under R501.6. Note that ENERGY STAR® is no longer a compliance path — HERS and Passive House are the two certification routes in Sandwich.

Detail sourced from the 2025 Massachusetts Stretch & Specialized Codes Technical Guidance (DOER, Sept 2025), Table R406.5 and Appendix RC.

Professional Duct Leakage Testing Services in Sandwich, Massachusetts

RESNET-certified duct leakage testing for new construction, HERS Ratings, Mass Save programs, and MA Stretch Code compliance in Sandwich, MA. We measure total duct leakage and leakage to outdoors — the two metrics required by all Massachusetts energy codes.

New construction in Sandwich with forced-air HVAC must achieve total duct leakage of 4% or less of system airflow under the MA Stretch Code. Our certified reports are accepted by all Massachusetts building departments and Mass Save administrators.

Our Duct Leakage Testing Process in Sandwich

  • Free Quote: Contact us for a transparent quote for duct testing in Sandwich. Package pricing with HERS Rating available.
  • Schedule Test: We schedule your duct blaster test at a convenient time — including pre-drywall tests.
  • On-Site Testing: Our technician connects the duct blaster fan and records total leakage and leakage-to-outside.
  • Report Delivery: Certified duct leakage report delivered within 24 hours — ready for permits, Mass Save, and HERS Rating.

Related Services in Sandwich

Frequently Asked Questions — Duct Leakage Testing in Sandwich

How much does duct leakage testing cost in Sandwich, MA?

Duct leakage testing pricing in Sandwich: Single-family homes $1,850–$2,500 (when combined with full HERS Rating package) · Standalone duct tests start from $250. Contact us for a free quote — package pricing available with blower door testing and HERS Rating.

What is the duct leakage limit in Sandwich?

Under the MA Stretch Code, total duct leakage in Sandwich must be 4% or less of system airflow. The IECC 2021 base code allows up to 8%. Leakage-to-outside must be 4 CFM25 per 100 sq ft under both codes.

How long does duct leakage testing take in Sandwich?

The on-site duct blaster test in Sandwich takes 1–2 hours. We deliver your certified report within 24 hours.

Is duct leakage testing required in Sandwich?

Yes. Duct leakage testing is required for new residential construction with forced-air HVAC in Sandwich under both the MA Stretch Code and IECC 2021 base code, and as a component of every HERS Rating.

Schedule Duct Leakage Testing in Sandwich

Contact HERS Rating Company for a free quote on duct leakage testing in Sandwich, MA. RESNET-certified, 24-hour turnaround.

Also Serving Nearby Cities

We provide Duct Leakage Testing services throughout the region. Nearby cities we serve: Bourne · Mashpee · Barnstable · Wareham

At HERS Rating Company, we are committed to providing the highest quality energy consulting services to homebuilders, architects, and developers across Massachusetts.

6175841809

24/7 Support

Newsletter

Sign up for our newsletter to receive exclusive updates, tips, and insights about energy-efficient building practices, financial incentives, and the latest energy code requirements in Massachusetts.

You have been successfully Subscribed! Ops! Something went wrong, please try again.

12 Pond St Ashland, MA 01721 United States

573 Washington St Quincy, MA 02169 United States

Scroll to Top